Complete Water analysis Meter - Good Laboratory Practice (GLP)
- US EPA Compliance
- Custom Calibration Points
The most important parameters needed for water analysis, especially in drinking water are now available in a portable meter. You can obtain lab performance in the field by using the HI 93102. It not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron and cyanuric acid (CYS). All this in the palm of your hand and in seconds! Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor. In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample. Up to 25 measured samples can be stored in memory together with time and date.
HI 93102 is supplied complete with glass cuvet, batteries and instructions. |
|
|
Range Turbidity | 0.00 to 9.99 NTU & 0.0 to 50.0 NTU* | Range Bromine | 0.00 to 8.00 mg/L | Range Free Chlorine | 0.00 to 2.50 mg/L | Range Total Chlorine | 0.00 to 3.50 mg/L | Range Cyanuric Acid | 0 to 80 mg/L | Range Iodine | 0.0 to 12.5 mg/L | Range Iron | 0.00 to 1.00 mg/L | Range pH | 5.9 to 8.5 pH | Resolution Turbidity | 0.01 & 0.1 NTU | Resolution Bromine | 0.01 mg/L | Resolution Free Chlorine | 0.01 mg/L | Resolution Total Chlorine | 0.01 mg/L | Resolution Cyanuric Acid | 1 mg/L | Resolution Iodine | 0.1 mg/L | Resolution Iron | 0.01 mg/L | Resolution pH | 0.1 mg/L | Accuracy (@20°C/68°F) Turbidity | ±0.5% NTU or ±5% of reading (whichever greater) | Accuracy (@20°C/68°F) Bromine | ±0.8 mg/L ±3% of reading | Accuracy (@20°C/68°F) Free Chlorine | ±0.03 mg/L ±3% of reading | Accuracy (@20°C/68°F) Total Chlorine | ±0.03 mg/L ±3% of reading | Accuracy (@20°C/68°F) Cyanuric Acid | ±1 mg/L ±15% of reading | Accuracy (@20°C/68°F) Iodine | ±0.1 mg/L ±5% of reading | Accuracy (@20°C/68°F) Iron | ±0.02 mg/L ±3% of reading | Accuracy (@20°C/68°F) pH | ±0.1 pH | Typical EMC Deviation Turbidity | ±2% Full Scale | Typical EMC Deviation Bromine | ±0.01 mg/L | Typical EMC Deviation Free Chlorine | ±0.01 mg/L | Typical EMC Deviation Total Chlorine | ±0.01 mg/L | Typical EMC Deviation Cyanuric Acid | ±1 mg/L | Typical EMC Deviation Iodine | ±0.1 mg/L | Typical EMC Deviation Iron | ±0.01 mg/L | Typical EMC Deviation pH | ±0.1 pH | Light Source | Pure Green LED | Light Life | Life of the instrument | Light Detector | Two Silicon Photocells | Battery Type / Life | 4 x 1.5V AA batteries/ 60 hours or 1,000 measureme | Environment | 32 to 122°F (0 to 50°C); RH 95% | Dimensions | 8.7 x 3.3 x 1.8" (220 x 83 x 46 mm) | Weight | 18 oz. (510 g) |
|
|
Weight:
1.13 Pounds |
Dimensions:
0.00(L) x
0.00(W) x
0.00(H) Inches |
Weight Disclaimer: *Weight may vary based on configuration. |
|
|
|