The HI 96733 is an auto diagnostic portable microprocessor meter that benefits from Hanna’s years of experience as a manufacturer of analytical instruments. It has the advanced optical system based on a special tungsten lamp and a narrow band interference filter that allows most accurate and repeatable readings. All instruments are factory calibrated and the electronic and optical design minimizes the need of frequent calibration. With the powerful CAL CHECKTM validation function, you are able to validate good performance of your instrument at any time. The validation procedure is extremely user friendly. Just use the exclusive HANNA ready-made, NIST traceable standards to verify the performance of the instrument and recalibrate if necessary. The instrument is splash waterproof and the tungsten lamp and filter units are protected from dust or dirt by a transparent cup. This makes the instruments fulfill field applications. Display messages aid the user in routine operation. The meter has an auto-shut off feature that will turn off the instrument after 10 minutes of non use in measurement mode or after 1 hour if left in calibration mode. The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit a cuvette with a larger neck making it easier to add both sample and reagents. The cuvette is made from special optical glass to obtain best results. The HI 96733 meter measures the ammonia nitrogen (NH3-N) content in water samples in the 0.0 to 50.0 mg/L (ppm) range. The method is an adaptation from ASTM Manual of Water and Environmental Technology, D1426-92, Nessler Method. The reagents are liquid form and are supplied in bottles. The amount of reagent is precisely dosed to ensure the maximum repeatability.
Order Information: HI 96733 is supplied with 2 cuvets, battery and instructions. Standards not included.
|
|
Range | | 0.0 to 50.0 mg/L (as NH3-N) | Resolution | | 0.1 mg/L | Accuracy | | ±0.5 mg/L ±5% of reading @ 25°C | Light Source | | Tungsten Lamp | Light Detection | | Silicon Photocell | Battery Type / Life | | 1 x 9V / approx. 40 hours of continuous use; auto-off after 10 minutes of non use | Environment | | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | Dimensions | | 192 x 102 x 67 mm (7.6 x 4 x 2.6") | Weight | | 290 g (10 oz.) | Method | | Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample | Typical EMC Deviation | | ±0.1 mg/L |
|
|
Weight:
0.63 Pounds |
Dimensions:
7.00(L) x
4.00(W) x
2.00(H) Inches |
Weight Disclaimer: *Weight may vary based on configuration. |
|
|
|