Responding to the user's requirements for analyzing high concentrations of chlorine, HANNA® offers HI 96771, a portable auto-diagnostic photometer which measures free chlorine from 0 to 5.00 and 0 to 500 mg/L range. The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. HI 96771 utilizes an adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-Cl. The reaction between free chlorine and the reagents causes a yellow tint (UHR) or pink tint (LR) in the sample. Order Information: HI 96771 are supplied with (2) sample cuvettes with caps, 9V battery and instructions. CAL CHECK™ standards and reagents sold separately
|
|
Range | | Free Chlorine: 0.00 to 5.00 mg/L; Chlorine ULTRA HIGH RANGE: 0 to 500 mg/L | Resolution | | Free Chlorine: 0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L; Chlorine ULTRA HIGH RANGE: 1 mg/L from 0 to 200 mg/L; 10 mg/L above 200 mg/L | Accuracy | | Free Chlorine: ±0.03 mg/L ±3% of reading @ 25°C; Chlorine ULTRA HIGH RANGE: ±3 mg/L ±3% of reading @ 25°C | Light Source | | Tungsten lamp | Light Detector | | Silicon photocell with narrow band interference filter @ 525nm | Power Supply | | (1) 9V battery | Auto-off | | After 10 minutes of non-use in measurement mode; After 1 hour of non-use in calibration mode; with last reading reminder. | Environment | | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | Dimensions | | 192 x 102 x 67 mm (7.6 x 4 x 2.6”) | Weight | | 290 g (10 oz.) | Method | | Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-Cl. | Typical EMC Deviation | | Free Chlorine: Free Chlorine; Chlorine ULTRA HIGH RANGE: ±1 mg/L |
|
|
Weight:
2.00 Pounds |
Dimensions:
4.00(L) x
10.00(W) x
4.00(H) Inches |
Weight Disclaimer: *Weight may vary based on configuration. |
|
|
|
SKU | Item | Price | |
HI96734C |
HI 96734C : KIT - FREE AND TOTAL CHLORINE PHOTOMETERS |
$370.00 |
|
HI96771C |
HI 96771C : Chlorine, Ultra-High Range Waterproof Photometer |
$355.00 |
|
HI95771-01 |
HI 95771-01 : UHR chlorine reagent set 100 test |
$25.00 |
|
HI95771-03 |
HI 95771-03 : UHR chlorine reagent set 300 tests |
$68.00 |
|
HI93701-01 |
HI 93701-01 : Chlorine, Free, DPD method Range: 0.00 to 2.50 mg/L (ppm) Reagent, Powder kit; 100 tests (Free Cl2) |
$24.00 |
|
HI93701-03 |
HI 93701-03 : Chlorine, Free, DPD method Range: 0.00 to 2.50 mg/L (ppm) Reagent, Powder kit; 300 tests (Free Cl2) |
$65.00 |
|
HI96734 |
HI 96734 : Free and Total Chlorine Photometers |
$235.00 |
|
|
|