HI 99181N is a skin pH meter from HANNA®, specifically designed for skin analysis. Essential for labs researching the biological compatibility of cosmetics and pharmaceuticals. HI 99181N provides affordable, fast, simple measurements without compromising precision.
HI 1414D/50 has a special flat tip electrode that permits perfect contact between probe and sample. Equipped with a built-in temperature sensor, meter readings are adjusted for temperature effects. The calibration is automatic at 1 or 2 points, selectable between 2 memorized buffer sets. A features an automatic step-by-step guide to calibration, enhanced with easy to understand messages and symbols.
The reading can be captured on the display with the HOLD feature. The user can select not only the pH calibration buffer set, but also the temperature measurement unit (°C or °F), This laboratory instrument measures in wide pH and temperature ranges, from -2.00 to 16.00 pH, and from -5.0 to 105.0 °C.
Battery life is more than 1500 hours and the percentage of remaining battery life is displayed at startup. HI 99181N turns off automatically after 8 minutes of inactivity.
- New Larger LCD
- Tutorial messages for calibration and setup
- Missing Probe Indicator
- New Rugged, thinner ergonomic case
- Faster/Easier battery replacement
Order Information:
HI 99181N is supplied with HI 1414D/50 pH electrode, pH 4 and pH7 buffer sachets, HI 700620 (2 x 20 mL sachet) and HI 700621 (2 x 20 mL sachet) cleaning solutions, batteries, rugged carrying case and instructions.
|
|
Range |
pH |
-2.00 to 16.00 pH |
Range |
Temperature |
-5.0 to 105.0°C / 23.0 to 221.0°F |
Resolution |
pH |
0.01 pH |
Resolution |
Temperature |
0.1°C / 0.1°F |
Accuracy |
pH |
±0.02 pH |
Accuracy |
Temperature |
±0.5°C (up to 60°C), ±1°C (outside); ±1.0°F (up to 140°F), ±2°F (outside) |
pH Calibration |
|
automatic, 1 or 2 point with 2 sets of memorized buffer values (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) |
Temperature Compensation |
|
Automatic, -5 to 105°C (23 to 221°F) |
pH Electrode |
|
HI 1414D/50, amplified, flat tip, with internal temperature sensor, 50mm (2.0") long body (included) |
Battery Type / Life |
|
3 x 1.5V AA / approx. 1500 hours of continuous use: auto-off after 8 minutes of non-use |
Environment |
|
0 to 50°C (32 to 122°F); RH max 100% |
Dimensions |
|
150 x 80 x 36 mm (5.9 x 3.1 x 1.4") |
Weight |
|
210 g (7.4 oz.) |
|
|
Weight:
4.00 Pounds |
Dimensions:
0.00(L) x
0.00(W) x
0.00(H) Inches |
Weight Disclaimer: *Weight may vary based on configuration. |
|
|
|